SHUT DOWN BUTTON
Emergency Shut Off Valve
Emergency Shut Off Valve
EMCO Wheaton’s F700 series of fuel emergency shut off valves guarantee operator safety while also maintaining high flow rates, low pressure drop and a long service life.
Simple design and quality components make them an ideal choice for oil majors and transporters of petroleum products.
Compartir
Safety by Design
Quality Components
High Flow Rate
Low Pressure Drop
Features & Benefits
Our emergency valves provide flow control at the bottom of tank truck compartments in the event of an accident.
All EMCO Wheaton designs are made from high-quality materials and incorporate solid design principles to maximize safety. Many of the oil industry’s most recognisable names depend on products in the F7000 series each day, acknowledging their durability and performance even after heavy repeat use.
Other key features include:
- Lightweight aluminium construction
- Diecast body and quality component materials for durability
- High lift poppet for maximum flow
- External shear groove meets TMMA and NTTC DOT 406 to limit product spillage in the event of an accident
- Double O-ring seals on camshaft for improved sealing and easy maintenance
- Removable bonnet assembly that allows seal change without removing the valve from the truck
- Screen filter fitted as standard on 4” range to prevent seal damage
- Viton seals are standard for compatibility with high-octane fuels and additives
Technical Info
The F7000 series include mechanical and pneumatic options. Variants include:
Mechanical Operation:
- F0335 - 3" 90°,
- TTMA Flanged F7000 - 4" 90°,
- TTMA Flanged F7001 - 4" 90°,
- Victaulic Outlet F7010 - 4" Straight,
- TTMA Flanged F7011 - 4" Straight,
- Victaulic Outlet
Pneumatic Operation:
- F7020 - 4" 90°,
- TTMA Flanged F7021 - 4" 90°,
- Victaulic Outlet F7023 - 4" 90°,
- TW Flanged F7024 - 4" 90°,
- TTMA Flanged F7033 - 4" 90° Intermediate,
- TW Flanged F7034 - 4" 90° Intermediate,
- TTMA Flanged F7043 - 4" 90° Low Profile,
- TW Flanged F7050 - 3" 90°,
- TTMA Flanged F7051 - 3" 90°,
- Victaulic Outlet F7063 - 4" Tee,
- TTMA Flanged
Specials
The GS version is designed to prevent tampering with pneumatic sequence signal. The sequence cannot be bypassed and only provides ‘open signal’ if the valve is in an open state. Please contact EMCO Wheaton for more details.
Applications
EMCO Wheaton’s fuel emergency shut off valves are developed specifically for oil companies and transports of petroleum products. They can be found fitted to tank trucks across the world.
Fuel Truck Loading and Unloading Procedures
Fuel loading and unloading procedures are safe and effective when using EMCO Wheaton’s range of products.
Aprende Más
Aftermarket
The transport and unloading of fuel are taxing jobs and even the best components will wear over time. That’s why EMCO Wheaton offers a full range of original spares and in-field service kits to keep critical equipment like emergency valves fully operational. Most repairs are simple and can be carried out on the road but don’t hesitate to contact us if you require specialist advice.
Service Kits
675707 - AIR CYLINDER INTERNALS GS TYPE
675708 - AIR CYLINDER INTERNALS LOW PROFILE GS TYPE
673300 - AIR BOX REPLACEMENT KIT F7023
673301 - AIR BOX REPLACMENT KIT F7033
673302 - AIR BOX REPLACMENT KIT F7043
607690 - CYLINDER E/V SEQUENCE ASSY F7063
672733 - KIT - F7020/21/50/51 AIR CYLINDER CAP
Manhole Covers & Accessories
EMCO Wheaton’s manhole covers provide an emergency vent for fuel tanks, keeping people safe should an accident occur.
Aprende Más
Overfill Prevention System - F2020
Our Overfill Prevention System incorporates the latest fast response optic self-checking electronics for preventing the overfilling of bottom loaded petroleum tanker compartments during the terminal loading process.
Aprende Más
Pneumatic Controls
Our Pneumatic Control Systems comprise of various air operated components used as control devices for actuating pneumatic valves, interlocking vehicle brakes or other pneumatic components with a guard bar or door actuation.
Aprende Más
Shut Down Button - Emergency Shut Off Valve
Designed to incorporate maximum safety, high flow, low-pressure drop, easy maintenance and offer a long service life.
Aprende Más
API Adapters
Lightweight one-piece aluminum body, hard anodized indexible nose ring and flat bottom set the standard in terms of design features and build quality.
Aprende Más
F0530 Vapor Adapters
Designed to minimize pressure drop and maximize the efficiency of the recovery of petroleum vapors during tanker loading and unloading.
Aprende Más
Product Grade Indicator
To be fitted directly above each loading or discharging API adaptor. It allows the operator to check and set the product grade for that tanker compartment. It also features integrated pneumatic control which opens the bottom valve for loading and unloading in one place.
Aprende Más
Vapor Transfer Vents to transfer displaced vapors
As a key component in the vapor recovery system, the vapor transfer vent (VTV), fitted to the Manhole Cover, provides the means to transfer displaced vapors to and from the tanker.
Aprende Más
COMBI-Cabinet
The new F2035 combi-cabinet has been designed to be compact and integrate the full control system into one location to eliminate dispersed operation and achieve a centralised control maximising space and, again, minimising weight.
Aprende Más
Features & Benefits
Features & Benefits
Our emergency valves provide flow control at the bottom of tank truck compartments in the event of an accident.
All EMCO Wheaton designs are made from high-quality materials and incorporate solid design principles to maximize safety. Many of the oil industry’s most recognisable names depend on products in the F7000 series each day, acknowledging their durability and performance even after heavy repeat use.
Other key features include:
- Lightweight aluminium construction
- Diecast body and quality component materials for durability
- High lift poppet for maximum flow
- External shear groove meets TMMA and NTTC DOT 406 to limit product spillage in the event of an accident
- Double O-ring seals on camshaft for improved sealing and easy maintenance
- Removable bonnet assembly that allows seal change without removing the valve from the truck
- Screen filter fitted as standard on 4” range to prevent seal damage
- Viton seals are standard for compatibility with high-octane fuels and additives
Technical Info
Technical Info
The F7000 series include mechanical and pneumatic options. Variants include:
Mechanical Operation:
- F0335 - 3" 90°,
- TTMA Flanged F7000 - 4" 90°,
- TTMA Flanged F7001 - 4" 90°,
- Victaulic Outlet F7010 - 4" Straight,
- TTMA Flanged F7011 - 4" Straight,
- Victaulic Outlet
Pneumatic Operation:
- F7020 - 4" 90°,
- TTMA Flanged F7021 - 4" 90°,
- Victaulic Outlet F7023 - 4" 90°,
- TW Flanged F7024 - 4" 90°,
- TTMA Flanged F7033 - 4" 90° Intermediate,
- TW Flanged F7034 - 4" 90° Intermediate,
- TTMA Flanged F7043 - 4" 90° Low Profile,
- TW Flanged F7050 - 3" 90°,
- TTMA Flanged F7051 - 3" 90°,
- Victaulic Outlet F7063 - 4" Tee,
- TTMA Flanged
Specials
The GS version is designed to prevent tampering with pneumatic sequence signal. The sequence cannot be bypassed and only provides ‘open signal’ if the valve is in an open state. Please contact EMCO Wheaton for more details.
Applications
Applications
EMCO Wheaton’s fuel emergency shut off valves are developed specifically for oil companies and transports of petroleum products. They can be found fitted to tank trucks across the world.
Fuel Truck Loading and Unloading Procedures
Fuel loading and unloading procedures are safe and effective when using EMCO Wheaton’s range of products.
Aprende Más
Aftermarket
Aftermarket
The transport and unloading of fuel are taxing jobs and even the best components will wear over time. That’s why EMCO Wheaton offers a full range of original spares and in-field service kits to keep critical equipment like emergency valves fully operational. Most repairs are simple and can be carried out on the road but don’t hesitate to contact us if you require specialist advice.
Service Kits
675707 - AIR CYLINDER INTERNALS GS TYPE
675708 - AIR CYLINDER INTERNALS LOW PROFILE GS TYPE
673300 - AIR BOX REPLACEMENT KIT F7023
673301 - AIR BOX REPLACMENT KIT F7033
673302 - AIR BOX REPLACMENT KIT F7043
607690 - CYLINDER E/V SEQUENCE ASSY F7063
672733 - KIT - F7020/21/50/51 AIR CYLINDER CAP
Related Products
Manhole Covers & Accessories
EMCO Wheaton’s manhole covers provide an emergency vent for fuel tanks, keeping people safe should an accident occur.
Aprende Más
Overfill Prevention System - F2020
Our Overfill Prevention System incorporates the latest fast response optic self-checking electronics for preventing the overfilling of bottom loaded petroleum tanker compartments during the terminal loading process.
Aprende Más
Pneumatic Controls
Our Pneumatic Control Systems comprise of various air operated components used as control devices for actuating pneumatic valves, interlocking vehicle brakes or other pneumatic components with a guard bar or door actuation.
Aprende Más
Shut Down Button - Emergency Shut Off Valve
Designed to incorporate maximum safety, high flow, low-pressure drop, easy maintenance and offer a long service life.
Aprende Más
API Adapters
Lightweight one-piece aluminum body, hard anodized indexible nose ring and flat bottom set the standard in terms of design features and build quality.
Aprende Más
F0530 Vapor Adapters
Designed to minimize pressure drop and maximize the efficiency of the recovery of petroleum vapors during tanker loading and unloading.
Aprende Más
Product Grade Indicator
To be fitted directly above each loading or discharging API adaptor. It allows the operator to check and set the product grade for that tanker compartment. It also features integrated pneumatic control which opens the bottom valve for loading and unloading in one place.
Aprende Más
Vapor Transfer Vents to transfer displaced vapors
As a key component in the vapor recovery system, the vapor transfer vent (VTV), fitted to the Manhole Cover, provides the means to transfer displaced vapors to and from the tanker.
Aprende Más
COMBI-Cabinet
The new F2035 combi-cabinet has been designed to be compact and integrate the full control system into one location to eliminate dispersed operation and achieve a centralised control maximising space and, again, minimising weight.
Aprende Más